Description
The flagship YELLOW JACKET® P51-870 TITAN® features a 4.3” full color touchscreen graphic display with digital and graphical representation of pressure and temperature measurements. It also features on-board data logging and standard vacuum sensor and measurements (vacuum sensor included). A 4-pak of hoses is included as well as two temperature clamps and a backpack carrying case for safe storage.
Measures high and low side pressures and temperatures
• Displays vapor and liquid saturation temperatures
• System superheat and subcooling calculations
• On board data logging; export to your computer through USB or to your phone via the YJACK VIEW® app for 40870, 40875 and 40877 (40860 uses the ManTooth® app)• Pressure hold mode displays rate of change for both vacuum and positive pressure measurements
• 4-way TITAN® valve block
• 126 refrigerant profiles stored in the instrument including new blends not currently on the REFPROP database.
• Backlit display with auto-dimming
• Auto shut-off
• Bluetooth® capability
• Optional vacuum sensor available (included with P51-870 TITAN®)
o Vacuum measurements, targets and leak testing
o High and low alarms
• Re-chargeable battery with battery life indicator
o Continuous use no backlight: 80 hours
o Continuous use full backlight: 4 hours (40870)
• US and international units (bar, psia, psig, kPa, MPa, kg/cm2)
• Maximum working pressure 700 psia (48.3 bar)
• USB charging port
• IP52 certified
• Robust housing
• Two year warranty
Additional features and benefits of the P51-870 TITAN®:
• 4.3” Full color touch screen display
• Digital and graphical representation of pressure and temperature measurements
• Vacuum sensor included
• Set of 4 manifold hoses included: (3) 1/4″ RYB and (1) 3/8″ yellow vacuum hose
• 40875 and 40877 include: (2) 5/16″ hoses RB
• Backpack carrying case included
IMPORTANT SET-UP INFORMATION: The touchscreen calibration of your new P51-870 may have been compromised during shipping. To re-calibrate, follow these quick steps:
1. When the device is powered on, press the power button three times in quick succession (this should power the device off).
2. Power the device back on to prompt calibration.
3. Tap the three flashing dots as they appear on the screen. For the best calibration, use a fine tip to tap the center of each dot.
When the calibration is complete the device will startup normally
Measures high and low side pressures and temperatures
• Displays vapor and liquid saturation temperatures
• System superheat and subcooling calculations
• On board data logging; export to your computer through USB or to your phone via the YJACK VIEW® app for 40870, 40875 and 40877 (40860 uses the ManTooth® app)• Pressure hold mode displays rate of change for both vacuum and positive pressure measurements
• 4-way TITAN® valve block
• 126 refrigerant profiles stored in the instrument including new blends not currently on the REFPROP database.
• Backlit display with auto-dimming
• Auto shut-off
• Bluetooth® capability
• Optional vacuum sensor available (included with P51-870 TITAN®)
o Vacuum measurements, targets and leak testing
o High and low alarms
• Re-chargeable battery with battery life indicator
o Continuous use no backlight: 80 hours
o Continuous use full backlight: 4 hours (40870)
• US and international units (bar, psia, psig, kPa, MPa, kg/cm2)
• Maximum working pressure 700 psia (48.3 bar)
• USB charging port
• IP52 certified
• Robust housing
• Two year warranty
Additional features and benefits of the P51-870 TITAN®:
• 4.3” Full color touch screen display
• Digital and graphical representation of pressure and temperature measurements
• Vacuum sensor included
• Set of 4 manifold hoses included: (3) 1/4″ RYB and (1) 3/8″ yellow vacuum hose
• 40875 and 40877 include: (2) 5/16″ hoses RB
• Backpack carrying case included
IMPORTANT SET-UP INFORMATION: The touchscreen calibration of your new P51-870 may have been compromised during shipping. To re-calibrate, follow these quick steps:
1. When the device is powered on, press the power button three times in quick succession (this should power the device off).
2. Power the device back on to prompt calibration.
3. Tap the three flashing dots as they appear on the screen. For the best calibration, use a fine tip to tap the center of each dot.
When the calibration is complete the device will startup normally