Carol Stream: (630) 534-4900 • Chicago: (773) 772-7400 • Crestwood: (708) 239-6200

LOW AMBIENT CONTROLER RXAD-A08

Product Number: 83117
Manufacturer Code: 47-100571-05
Please login to see prices
Product Group : Temperature Limit Auto Reset
General Information
Product Group : Temperature Limit Auto Reset
Reset : Auto
Type : Low Pressure Limit - Low Ambient Control
Cable
Cable Length : 36 in
Connections
Capillary Tube Included : Yes
Connection Size Refrigerant : 1/4 in
Connection Type Refrigerant : Flare (Female SAE)
Electrical
FLC at 120VAC : 5.80 A
FLC at 230VAC : 2.90 A
LRC at 120VAC : 34.80 A
LRC at 230VAC : 15.0 A
Pilot Duty Rating at 24V : 125 VA
Pilot Duty Rating at 120V : 375 VA
Pilot Duty Rating at 230V : 375 VA
Logistical Information
Packaging Height : 2.10 in
Packaging Length : 5.45 in
Packaging Width : 3.15 in
Shipping Weight Actual : 0.28 lb
Shipping Weight Dimensional : 0.28 lb
Measurements
Capillary Tube Length : 36 in
Pressure
Burst Test Pressure : 5000 Psig
Close : 380 Psig
Open : 250 Psig
Proof Test Pressure : 800 Psig
Tolerance Close Pressure : +/- 10 Psig
Tolerance Open Pressure : +/- 10 Psig
Wire
Wire Size : 18 AWG
Description
Product Number Manufacturer Code Product Description Price Stock Level
MAIN LIMIT - AUTO RESET TEMP 170/130
Appears after registration
Appears after registration
MAIN LIMIT - AUTO RESET TEMP 160/140
Appears after registration
Appears after registration
AUTO RESET LIMIT 180/100
Appears after registration
Appears after registration
AUTO RESET LIMIT 190/150
Appears after registration
Appears after registration
AUTO RESET LIMIT 200/120
Appears after registration
Appears after registration
145-165F AUTO LIMIT SWITCH
Appears after registration
Appears after registration
LIMIT CONTROL (160/140F)
Appears after registration
Appears after registration
LIMIT CONTROL (170/150F)
Appears after registration
Appears after registration
LIMIT CONTROL (150/130F)
Appears after registration
Appears after registration
LIMIT CONTROL (200F)
Appears after registration
Appears after registration
LIMIT CONTROL (190/170F)
Appears after registration
Appears after registration
LIMIT (160/140F)
Appears after registration
Appears after registration
LIMIT (170/150F)
Appears after registration
Appears after registration
LIMIT CONTROL (180/160F)
Appears after registration
Appears after registration
LIMIT CONTROL (200/180F)
Appears after registration
Appears after registration
HEAT ASST LIMIT (105/95F) BURNER COMPARTMENT
Appears after registration
Appears after registration
100-110F AUTO LIMIT SWITCH
Appears after registration
Appears after registration
HEAT ASST LIMIT (110/100F) BLOWER LIMIT
Appears after registration
Appears after registration
LIMIT CONTROL (300F)
Appears after registration
Appears after registration
ROLLOUT LIMIT - 250F
Appears after registration
Appears after registration
LOW AMBIENT CONTROLER RXAD-A08
Appears after registration
Appears after registration
LIMIT SWITCH - AUTO RESET (FLANGED AIRSTREAM) YELLOW
Appears after registration
Appears after registration
LIMIT CONTROL W/HEATER
Appears after registration
Appears after registration
LIMIT SWITCH - AUTO RESET (FLANGED AIRSTREAM - LOW VOLTAGE) - YELLOW
Appears after registration
Appears after registration
Limit Switch - Auto Reset (Board Mount)
Appears after registration
Appears after registration
LIMIT SWITCH - AUTO RESET (BOARD MOUNT) - YELLOW/YELLOW
Appears after registration
Appears after registration
LIMIT SWITCH - AUTO RESET 120/20
Appears after registration
Appears after registration
LIMIT CONTROL - ENCLOSED DISC
Appears after registration
Appears after registration