Description
Product Number:
83117
Manufacturer Code:
47-100571-05
Product Group : | Temperature Limit Auto Reset |
---|
General Information
Product Group : | Temperature Limit Auto Reset |
---|---|
Reset : | Auto |
Type : | Low Pressure Limit - Low Ambient Control |
Cable
Cable Length : | 36 in |
---|
Connections
Capillary Tube Included : | Yes |
---|---|
Connection Size Refrigerant : | 1/4 in |
Connection Type Refrigerant : | Flare (Female SAE) |
Electrical
FLC at 120VAC : | 5.80 A |
---|---|
FLC at 230VAC : | 2.90 A |
LRC at 120VAC : | 34.80 A |
LRC at 230VAC : | 15.0 A |
Pilot Duty Rating at 24V : | 125 VA |
Pilot Duty Rating at 120V : | 375 VA |
Pilot Duty Rating at 230V : | 375 VA |
Logistical Information
Packaging Height : | 2.10 in |
---|---|
Packaging Length : | 5.45 in |
Packaging Width : | 3.15 in |
Shipping Weight Actual : | 0.28 lb |
Shipping Weight Dimensional : | 0.28 lb |
Measurements
Capillary Tube Length : | 36 in |
---|
Pressure
Burst Test Pressure : | 5000 Psig |
---|---|
Close : | 380 Psig |
Open : | 250 Psig |
Proof Test Pressure : | 800 Psig |
Tolerance Close Pressure : | +/- 10 Psig |
Tolerance Open Pressure : | +/- 10 Psig |
Wire
Wire Size : | 18 AWG |
---|
Product Number | Manufacturer Code | Product Description | Price | Stock Level |
---|---|---|---|---|
MAIN LIMIT - AUTO RESET TEMP 170/130
|
Appears after registration
|
Appears after registration
|
||
MAIN LIMIT - AUTO RESET TEMP 160/140
|
Appears after registration
|
Appears after registration
|
||
AUTO RESET LIMIT 180/100
|
Appears after registration
|
Appears after registration
|
||
AUTO RESET LIMIT 190/150
|
Appears after registration
|
Appears after registration
|
||
AUTO RESET LIMIT 200/120
|
Appears after registration
|
Appears after registration
|
||
145-165F AUTO LIMIT SWITCH
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (160/140F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (170/150F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (150/130F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (200F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (190/170F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT (160/140F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT (170/150F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (180/160F)
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (200/180F)
|
Appears after registration
|
Appears after registration
|
||
HEAT ASST LIMIT (105/95F) BURNER COMPARTMENT
|
Appears after registration
|
Appears after registration
|
||
100-110F AUTO LIMIT SWITCH
|
Appears after registration
|
Appears after registration
|
||
HEAT ASST LIMIT (110/100F) BLOWER LIMIT
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL (300F)
|
Appears after registration
|
Appears after registration
|
||
ROLLOUT LIMIT - 250F
|
Appears after registration
|
Appears after registration
|
||
LOW AMBIENT CONTROLER RXAD-A08
|
Appears after registration
|
Appears after registration
|
||
LIMIT SWITCH - AUTO RESET (FLANGED AIRSTREAM) YELLOW
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL W/HEATER
|
Appears after registration
|
Appears after registration
|
||
LIMIT SWITCH - AUTO RESET (FLANGED AIRSTREAM - LOW VOLTAGE) - YELLOW
|
Appears after registration
|
Appears after registration
|
||
Limit Switch - Auto Reset (Board Mount)
|
Appears after registration
|
Appears after registration
|
||
LIMIT SWITCH - AUTO RESET (BOARD MOUNT) - YELLOW/YELLOW
|
Appears after registration
|
Appears after registration
|
||
LIMIT SWITCH - AUTO RESET 120/20
|
Appears after registration
|
Appears after registration
|
||
LIMIT CONTROL - ENCLOSED DISC
|
Appears after registration
|
Appears after registration
|